A4 SIZE Printout ,INTERPRETIVE 12 CHANNEL ELECTROCARDIOGRAM ECG/EKG MACHINE. The CardioCare 2000 is an economically priced interpretive 12 channel electrocardiogram (ECG/EKG) machine that does not compromise on performance. Suitable for use in private practice, the ER, or hospitals. The CardioCare 2000 is designed for maximum ease of use and convenience.
ECG leads |
12 lead, simultaneous ECG and acquisition |
Dimension |
296 (W) x 305.5 (H) x 92.5 (D)mm, Approx.2.98 kg |
Recording channel |
3, 6, 12 channel and 1 channel (60 sec) |
Sensitivity |
5, 10, 20, auto (1-aVF: 10, V1-V6: 5) mm/mV, 12.5, 25, 50 mm/S |
Sampling rate |
500 samples/sec |
Filters |
AC (50/60Hz, -20dB or better) Muscle (25 - 35Hz, -3dB or better) Base line drift (0.1 Hz, -3dB or better) Low pass filter (off, 40Hz, 100Hz, 150Hz) |
Display |
2 x 16 character backlit LCD Display |
LCD display |
Sensitivity, speed, filter status, HR, printing form, rhythm lead |
LED indicator |
Signal quality, power source, battery |
Keyboard |
Membrane keyboard, Alphanumeric and symbol available |
Patient data |
ID, name, age, sex, height, weight |
Basic measurement |
Heart rate, PR int, QRS dur, QT/QTc, P-R-T axis |
Recorder |
Thermal print head, Thermal roll paper Report papers : width : A4 : 210mm or 8.5" , length : A4 : 300mm or 11" Effective writing width: 204mm Resolution : Vertical : 8 dots/mm, Horizontal : 16 dots/mm |
Electrical |
Internal noise : 20 V(p-p)max Internal circuit: Floating input Isolated and defibrillation protected Input impedance : > 10MW Input voltage range : > + 5 mV Common Mode Rejection : > + 100 dB DC offset voltage range : > + 300 mV Time constant : 3.2sec Patient leakage current : < 10 mA Frequency response 0.05-150Hz |
Signal quality control |
Disconnected lead detection |
Power |
Power supply : AC or built-in Battery (option) Power requirement : 100 - 240 Vac, 50/60Hz, 1.0 - 0.5 A Power consumption : 60W max |
Battery |
1 hour of normal use (approximately 100 automatic ECG printouts) |
Communication |
PC connection with RS-232 interface and LAN |
Safety |
Class I, Type BF |
Conformity |
CE, CSA, FDA, KFDA, SFDA, CCC |
Environment |
Operating humidity : 30 - 85 % Operating Temperature : 10 - 40 C Atmospheric pressure : 70 - 106 KPa |
Standard accessory |
Power cord 1 EA, Patient cable 1 EA, Limb 1 set (4 EA), Chest ball 1 set (6EA), Chart paper 1 EA, Operation manual 1 EA |
Options |
Rechargeable battery, Cart, Hanger, Bag, PC S/W |
* Specifications can be changed without prior notification