Working Hours: 10AM - 6 PM (or)
Fill Service Request Form
A brilliant machine equipped with Electronic gas mixing. Advanced, modular and Robust design fulfil all the requirement of the Anaesthetist in the operation theatre and operating Rooms.
· Double TFT display for Aneasthesia monitoring and Vital parameters
· Electronic Flow meter for the graphical representation of O2, N2O & Air with fresh gas flow optimization feature
· Backup manual O2 control in case of Battery/Electricity failure
· Electronic and Mechanical Flush
· Electronic/ Digital Hypoxia Guard
· Twin Selecta tec mounting for agent specific temperature and pressure compensated vaporisers
· NIST inlets for piped medical gases for O2, N2O & Air
· Common gas outlet (CGO)
· Open/Close change over switch for convenient switch-over from open to closed system
· Suitable for open, semi-open & closed-circuit system application
· Electrical outlets for running other medical equipment
· Auxiliary O2 & Air outlet with flow meter
· Work surface lighting
· Supports Low-Flow Anaesthesia
· Large Workbench
· One Key FiO2 setup, automatic adjust oxygen flow to maintain FiO2, if fresh gas flow has changed
· Anaesthetic Gas monitoring (optional)
Patient Safety Features
· Electronic gas mixing with electronic Hypoxia guard
· Audio Visual Alarm for O2 failure
· Electronic and mechanical O2 Flush 30-70 LPM O2 Flow
· System Pressure Relief at 125 cmH2O
· AGSS
· High-luminance and wide display
· 15.6” Touch Screen
· Ventilation Modes - V-CMV, P-CMV, V-SIMV, P-SIMV, PRVC, PSV & Manual/ Spont
· Monitoring Parameters (Measured values) VT, Freq, FiO2, Ppeak, MV, PEEP, Pplat, Pmean, Compliance and Resistance
· Tidal volume range from 10ml to 1500ml suitable for Adult, Pediatric & Neonates
· Volume compensation and electronic PEEP.
· Automatically compensates for system leak and the compliance change in the circuit
· Fresh gas flow compensation
· Ascending bellows provides immediate visual information on the adequacy of fresh gas flow and gives an indication of any system leak.
· Cardiac By-Pass mode
· Integrated Pressure, Volume and Oxygen monitoring
· Self test, leak test and compliance test
· Adult, pediatric & Neonatal mode
· Waveforms: Flow-Time, Volume-Time, Pressure-Time
· Spirometry Loops: Flow-Volume, Volume-Pressure, Pressure-Flow.
· Setting Parameters: VT (Tidal Volume), Frequency, I:E ratio, Tip (Inspiratory pause time), Pmax, PEEP, Vtr (Triggering flow sensitivity), SIGH, Tapn, Ptrig (Pressure trigger) PLimit, Psupp.
· Alarm Parameters: Sustained pressure, Airway pressure (high & low), FiO2 (high & low), MV (high & low), Frequency (high & low), Apnea, A/C failure, Battery low, O2 failure alarm
Integrated Multipara Monitor
· 15.6 inches Touch screen
· ECG- 3/ 5/ 12 Leads
· NIBP
· SpO2
· Respiration
· Dual Temperature
· Dual IBP (Optional)
· Graphical & Tabular Trend-168hrs
Integrated Breathing System
· Bag/ Ventilator switch -Easy changeover from ventilator to bag
· Integrated airway pressure manometer
· Moisture drain valve
· Quick release sodalime canister system
· Autoclavable
· Fully calibrated APL valve (range 0–70cmH O2)
· Built-in O2 monitor sensor port
· Automatic ventilator switching from circle absorber
· Single canister system
· Heated circuit
Storage Space: Three spacious drawers to hold essential anaesthesiakit and accessories
Castors: Large roller bearing anti-static castors with front brakes
Cylinder Yokes: Color coded gas specific (pin indexed) yokes with sliding stainless steel clamping bars for easy handling. Holding 1 (One) each for O2 and N2O, 5Ltr water capacity cylinders
Non-return / Pressure Relief Valve: Minimises risk of back flow of gases, blows off when pressure exceeds 125 Cm H2O
Oxygen Flush: Electronic and mechanical O2 flush 30-70 LPM O2 flow
Common Gas Outlet (CGO): Conveniently located CGO with ISO tapers for 22 & 15mm connections
Pipe Line Gas Inlets: Non-Interchangeable Screw Threaded (NIST) pipeline inlets one each for O2, N2O and Air. In case of drop in piped gas pressure the pin index cylinders take over automatically
Hypoxia Guard: Electronic/ Digital Hypoxia guard
Gas Mixing: Electronic flowmeter for the graphical representation of O2, N2O and Air.
Selectatec Brackets: Twin Selectatec Block
Breathing Circuits: Bains Circuit & Circle Absorber Y-Circuit provided as standard
· Tidal Volume 5–1600 ml
· Frequency 1–100 bpm
· I : E Ratio 4:1–1:8
· PEEP OFF, 1.0 – 30 cmH2O
· Inspiratory Pause 0–50% of Ti
· Flow <180L/min
· Power 100–240vAC, 50/60Hz, 6.5A (Max.)
· Battery back-up Ventilator 120mins
Regarding any queries.