Working Hours: 10AM - 6 PM (or)
Fill Service Request Form
· Three Gas Anaesthesia Machine with provision for O2, N2O & Air
· Main Driving gas can be air, hence reduce running cost of oxygen
· Smart Gas Shift Technology: In case main Air gas fails, auto shift to secondary gas O2
· Five Tube flow meter assembly with Anti Hypoxia Guard with N O shut off in case O fail
· Advance ventilator with full range of modes VCV, PCV, SIMV, PSV, Manual, Standby
· 9 Inch Color Touch screen for display waveforms (PT, FT, VT ) & Loops (PV, FV)
· Advanced proportional valve technology with tidal Volume compensation & precise flow
· Control to ensure accurate ventilation delivery from 20ml-2000ml
· Lithium Ion Battery backup 3 hours
· Electronic PEEP & Fio2 Monitoring
· Switchable Auxiliary Common gas outlet ACGO)
· Emergency oxygen flush flow between 35 to 70 LMP
· Twin Selectatec type vaporizers manifold with interlock system
· Inbuilt Pin Index Yokes for O2 & N2O
· Inbuilt Dual Drawers with big storage space
· Integrated circle observer (1.5 L) with APL Valve and manual/Vent switch
VENTILATOR PARAMETERS
· Driven mode: Pneumatically driven electronically control
· Touch Screen + Rotary knob + Key pad for simple operation
· Patient Type: Adult & Paediatric
· Tidal Volume (VT): 20ml~1500ml
· Display Size: 9 Inch colour Touch screen
· Ventilation mode: VCV, PCV, SIMV-V, SIMV-P, PSV
· STANDBY, Manual/Spontaneous, ACGO
· Pressure Control: 5~100cmH2O
· Pressure support: 5~60cmH2O
· Electronic PEEP: OFF, 3~40 cmH2O
· Trigger: Flow and Pressure trigger
· Frequency (f): 0~100 bpm, Frequency SIMV: 4~60 bpm
· I: E ratio: 10:1~1:10
· Inspiratory time: 0.5~ 5S, Inspiratory pause: 0~50%
· Case START/STOP key with timer
MONITORED PARAMETERS
· Parameters: Ppeak, Pmean, PEEP, Pplatu, MV, MV_spont,
· MV_ cont, TVi, TVe, Freq, Freq_spont, Freq_cont , Fio2,Peak
· Flow, Ti, Te, I:E, Resistance & Compliance , Gas Pressure,
· Etco2 (optional)
· Waveforms: P-T, F-T,V-T & CO2-T (Optional)
· Loops: P-V, F-V
· Alarm Recall & Review
ALARMS
· 3 levels audio visible alarm
· Volume: Vte high/ low, MV high/low
· Pressure: Ppeak high/low, PEEP high/low, Gas Pressure fail
· Frequency high/low, Fio2 high/low, Apnea time, alarm mute,
· Power: AC Power fail, Low Battery
VAPORIZER
· Dual Position Mounting: Tool-free installation
· Selectatec compatible with interlock.
· Agent type: Halothane, Isoflurane, Sevoflorane,
· Filling type: Pour-fill, Easy-fill and Quick-fill.
PNEUMATIC SPECIFICATION
· Operational Modes: Closed & Semi Closed circuit system
· O2/ N O /Air Pipeline Gas Supply: 0.23Mpa~0.6MPa
· O2, N O Cylinder Gas Supply: Pin indexed yokes
· Pressure gauge: 3 nos. for pipeline, 2 nos. for cylinder
· Flow Meter: Cascade Flow Meter for O2, N2O & Single for Air
· Oxygen: Low Flow - 0.1~1.0 lpm & High Flow - 1~10 lpm
· N O: Low Flow - 0.1~1.0 lpm & High Flow - 1~10 lpm
· Air: 0~10 lpm
· Hypoxic guard system: Mechanical type provides minimum 25% concentration of O2 in O2/N2O mixture.
· Method : Proportionate reduce N2O with reduction in O2 flow
· O2 gas supply failure alarm: O2 pressure ≤ 0.23MPa
· N2O cut off: N2O cut off with O2 gas supply pressure fail
· O2 flush: 35~75L/min
· Switchable ACGO: ISO 22 mm OD and 15 mm ID
· CO2 absorbent: Quick release type with volume 1.5L.
· Highly integrated design reduces leaks and misconnects
· Bag/Vent switch: switch for manual and mechanical ventilation.
· Integrated Adjustable Pressure Limiting (APL) valve: ≤ 6KPa
GENERAL
· Dimension: 1400 X 800 X 650 mm (HXWXD)
· Drawer Size Internal: 400 X 410X 170 mm (LXWXD)
· Casters: 4 inch diameter, with Front Locking brakes at front
· DIN rail at both side of machine allow for flexibility and ease of mounting patient monitor
· Power Supply: AC100~240±10%, 50/60 Hz, 1A, 100VA
· Battery: 9.6V /3.2AH Lithium Ion Phosphate backup > 3 hours
· Communication: USB & VGA
· Weight: 90Kg
SAFETY STANDARD
· Basic: In accordance with IEC 60601-1, 2 & EMC 60601-2
· Unit Type: Class, Type B, IPX0
· Working Environment: Temperature: 10-40 C
· RH: 10-90% non condensing
Regarding any queries.