Basic ICU Ventilator with Compressor from Allied Model : Jupiter Ventilator

Basic ICU Ventilator with Compressor from Allied Model : Jupiter Ventilator
Available for sale in Telangana only

Ventilator with A-CMV Mode,with Compressor for OP poisoning, Snake bites etc An ISO 13485, CE approved product .For selecting version without compressor,click in SELECT BOX.

Availability: In stock
SKU: ICU-VENT-ALLD
Non Returnable

Product Video


SPECIFICATIONS

ICU Ventilator from Allied Medical Ltd ,Model: Jupiter Ventilator , comes with a Built in compressor with CMV & Assist control modes.

“Time cycled pressure limited electronically controlled ventilator”

  • Pneumatically Driven Ventilator
  • Modes : A-CMV, Standby, Manual
  • Driven from pipeline/cylinder/ Air compressor
  • Mains and battery operated.
  • Bar graph displays dynamic airway pressure showing uppe and lower pressure limits.
  • Settable parameters - BPM, I:E ratio pressure limits and
  • inspiratory flow rates
  • 60% & 100% FiO2 settings. 
  • Built-in audio-visual alarms .
  • Medical Air Compressor included
  • Humidifier optional

 Technical Specifications

Tidal Volume 50ml–1500ml

Display 3.2" Mono-chromatic

Modes A-CMV, Standby and Manual

Minute Volume with 60% 3–20 Ltr/min

Minute Volume with 100% O2–15 Ltr/min 2

Frequency 1–100BPM

I:E Ratio 4:1–1:10

Inspiratory gas flow control 0.1–1.0 L/Sec

Built-in pressure relief valve 70cmH2O 

Patient Trigger (-)5cmH2O (Fixed) 

Supply pressure 280–700 kPa (45–100 psi)

Graphical Pressure indication (-)10–80cmH2O (Bar graph)

Power Supply 220V–240V AC 50Hz

Internal Battery Backup 4hrs.

Alarms :

Low Airway Pressure (Apnea) 3–25cmH2O (Adjustable) 

High Airway Pressure 15–80cmH2O (Adjustable) 

Low Supply Gas Pressure

Alarm Mute 120 Sec except for

Low Supply Gas Pressure

Note: once alarm condition is rectified audio alarm will stop and

visual alarm will continue till reset button is pressed.

Inverse Ratios

The ventilator has the ability to adjust substantially when clinical

conditions require inverse I:E.

Inspiratory flow cut off

The inspiratory phase changes to expiratory in case the dynamic

pressure reaches the high-pressure limit. High-pressure Audio-visual

alarm will also be activated.

Apnea alarm/ low airway pressure alarm

If the dynamic pressure fails to go above the low-pressure limit with in

15sec, then the low airway audio visual pressure alarm will be activated.

Works on A-CMV

With the Preset (-) 5 cmH2O of trigger level the ventilator has the ability to synchronize with the patient with the patient breath.

 