Customer Care: +91 8008895680 | Service: 8008895079

Working Hours: 10AM - 6 PM (or)
Fill Service Request Form

Service: 8008895079
Working Hours: 10AM - 6 PM (or)
Fill Service Request Form

Available Products Request for Service Download DIGITAL CATALOGUE of Complete Medical Equipments
Welcome Guest
Search Products

My Account

Product Categories

Patient Monitor from Bird Meditech Model: BM-K15

Patient Monitor from Bird Meditech Model: BM-K15

Availability: In stock
SKU: PM-BM-K15
Non Returnable

Features

·         15 high resolution display with LED backlight 9-waveform on screen touch screen optional

·         User customized NIBP measuring cycles up to 5-phase

·         Versatile clinical calculations for application convenience

·         9 traces on-screen waveforms and maximal up to 13

·         Data export and software upgrade

·         HL7 protocol, Bed to bed view and 12-lead ECG available

·         360-degree visible indicator with 3-level alarm

·         Li-ion battery up to 2.5 hours continuous monitoring

·         Integral 3-channel thermal recorder

Specifications

ECG

·         Input dynamic range: ±(0.5mVp~5mVp)

·         Differential input impedance: ≥10MΩ

·         Bandwidth: 0.05~150Hz (Diagnostic)

·         0.5~40Hz (Monitoring)

·         1~20Hz (Operation)

·         CMRR: ≥90dB (Diagnostic)

·         ≥105dB (Monitoring & Operation)

·         Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto

·         Sweeping speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s

·         HR measuring range: 15~350bpm

·         HR accuracy: ±1% or ±2bpm, whichever is greate

·         Pacemaker pulse detection and rejection function

 

RESP

·         Measuring range: 0~120rpm

·         Measuring accuracy: ±5% or ±2 rpm, whichever is greater

 

TEMP

·         Measuring range: 21.0~50.0°C

·         Measuring accuracy: ±0.2°Cfrom 25~45°C

 

NIBP

·         Technique: Oscillometric method

·         Typical measurement time:

·         NIBP measuring range SYS: 40~275mmHg (Adult), 40~200mmHg (Pediatric), 40~135mmHg (Neonate)

·         NIBP measuring range DIA: 10~210mmHg (Adult), 10~150mmHg (Pediatric), 10~95mmHg (Neonate)

·         NIBP measuring range MAP: 20~230mmHg (Adult), 20~165mmHg (Pediatric), 20~110mmHg (Neonate)

·         NIBP measuring accuracy (mean difference): ±5mmHg

·         NIBP measuring accuracy (standard deviation): 8mmHg

·         NIBP measurement mode: Manual, Auto, STAT, Multi-cycle mode

·         Auto measuring intervals: 1-480min

 

SpO2

·         Technique: Dual-wavelength optical method

·         Measuring range: 0%~100%

·         Measuring accuracy: Arms is not greater than 2% for

·         SpO2 range 70~100%.

·         PR measuring range: 30~250bpm

·         PR measuring accuracy: ±2bpm or ±2%, whichever is greater

·         Low perfusion performance: As low as 0.3%

 

CO2

·         Technique: Infrared optical method

·         Sampling mode: Sidestream or Mainstream

·         Measuring range: 0~150mmHg

·         Measuring accuracy: 0~40mmHg ±2mmHg, 41~70mmHg ±5% of reading, 71~100mmHg ±8% of reading, 101~150mmHg ±10% of reading

·         Flow rate: 50ml/min ±10 ml/min (Sidestream)

 

Cerebral State Monitoring (CSM)

·         EEG sensitivity: ±400µV

·         Noise level: <2µVp-p, <0.4µV rms (1~250Hz)

·         CMRR: >140dB

·         Input impedance: >50Mohm

·         CSI and update: 0-100. filter: 6-42Hz, 1 sec. update

·         EMG%: 0-100 (logarithmic) filter: 75-85 Hz, 1 sec. update.

·         BS%: 0-100. filter: 2-42 Hz, 1 sec. update

 

IBP

·         Technique: Strain gauge transducer

·         Input sensitivity: 5μV/V/mmHg

·         Measuring range: -50~300mmHg

·         Measuring accuracy: ±2% or ±4mmHg, whichever is greater

·         Measuring positions: ART, RAP, PA, LAP, CVP, ICP, AUXP1, AUXP2

·         Calibration: zero calibrating

 

Cardiac Output (C.O.)

·         Blood temperature measuring: range: 23-43°C, accuracy: ±0.5°C

·         Injecta temperature measuring: range: 0-20°C, accuracy: ±0.5°C

·         Measuring range: 0.2~20 L/min

·         Measuring accuracy: ±0.2 L/min or ±10%, whichever is greater

 

Other

·         Power supply: AC 100V-240V, 50/60Hz, 60VA

·         Built-in lithium battery: 11.1V/4400mAh

·         Display: 12.1 inch TFT display

·         Alarming method: 3 levels audible-visible alarm

·         Networking: Ethernet

 

Standard configuration

ECG, Respiration, SpO2, PR, NIBP, Temperature

Options

Touch Screen, 2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, 12-lead ECG,Cardiac Output, Cerebral State Monitoring, Central Monitor Station,Multi-Gas Monitoring

 

 

Related Products

Request Demo

Request Quotation

Call us now for a free no-obligation chat.

Regarding any queries.

+91 8008895680
© 2024 BuyXavier, All Rights Reserved.