Working Hours: 10AM - 6 PM (or)
Fill Service Request Form
with remote sensing Tab for charting the real time drug delivery of patient, so anaesthetist can monitor the workstation from any where within the Hospital.
|
Anaesthesia
Workstation 3 gas system, Model: Jupiter Plus Next Gen, from Allied Medical with remote sensing Tab for charting the real time drug delivery of
patient, so anaesthetist can monitor the workstation from any where within
the Hospital. ISO 13485:2003, CE approved, WHO GMP
Standards Optional: Patient Monitor & Vaporizer FEATURES:
·
Larger,
Clearer user Interface ·
10.1
Inch high resolution display for excellent visibility across the OT ·
Clear
presentation of parameters, waveforms, and trends. ·
Reduces
eye strain during long procedures. ·
Quick
Release CO2 Canister System ·
Heater
integrated Circle Absorber ·
Built-in
flow sensor with no external tubing ·
Reduced
clutter and fewer connection points. ·
Enhanced
durability and long-term performance
TECHNICAL
SPECIFICATIONS: ·
Storage
Space: Two spacious drawers for keeping essential anesthesia kit /
accessories ·
Castors
& Foot Rest: Large roller bearing and Castors with front brakes &
foot rest ·
Writing
Surface: Wide table top for writing ·
Monitor
shelf: Wide monitor shelf at eye level. ·
Cylinder
Yokes: Color coded gas specific (pin indexed) yokes with sliding stainless
steel clamping bars for easy handling. Holding One O2 and One N2O 5 Ltrs.
water capacity cylinders. ·
Non-return/
Pressure Relief Valve: Minimizes risk of back flow of gases, blows off when
pressure exceeds 125 Cm H2O ·
Regulators:
Designed for higher efficiency, long service life and reliability for O2 and
N2O ·
O2
Flush: Emergency oxygen flush switch at table level to give 25-75 Ltrs/min
for emergencies ·
O2
Failure Warning Alarm: Self activated electro-pneumatic audio visual warning
device to indicate drop in O2 pressure below 2.5 Bar ·
Nitro
Lock: It enables N2O to cut off if Oxygen fails ·
Hypoxic
Guard: Mixing device to proportion the N2O in such a way that minimum of 25%
O2 is always present in the breathing gas mixture ·
Common
Gas Outlet (CGO): Conveniently located CGO with ISO tapers for 22 & 15mm
connections ·
Pipeline
Gas Inlets: Non-interchangeable screw threaded (NIST) pipeline inlets. In case
of drop in piped gas pressure the pin index cylinders take over automatically ·
Pressure
Gauges: Larges diameter, color coded gauges fitted at convenient angle for
better visibility and clarity. One for each of the pin indexed yokes and one
each corresponding to piped gas inlet ·
Selectatec
Brackets: Twin Selectatec Block ·
Breathing
Circuits: Bains and Closed circuit provided as standard
CASCADE FLOW METER: ·
Oxygen
Low Flow: 0.05 - 1.0 lpm ·
Oxygen
High Flow: 1-10 lpm ·
N2O
Low Flow: 0.05-1.0 lpm ·
N2O
High Flow: 1-12 lpm ·
Air:
0.2 - 15 lpm
PHYSICAL
SPECIFICATION: ·
Dimensions
(mm): 1370 (H) x 960 (W) x 860 (D) ·
Work
Surface(mm): 842 (H) x 480 (W) x 220 (D) ·
Drawer
(mm) 104 (H) x 335 (W) x 306 (D) ·
Weight:
100 Kg.
VENTILATOR TECHNICAL
SPECIFICATIONS: ·
Modes:
VCV, PCV, V-SIMV+PSV, P-SIMV+PSV, PSV (Optional), AC-V, AC-P and Manual ·
Electronic
PEEP: Settable, 3-30 cmH2O ·
Waveforms:
Pressure, Flow and Volume ·
Loops:
Pressure vs Volume, Flow vs Volume ·
Compensation:
Fresh Gas and Compliance ·
Tidal
Volume: 20ml - 1500ml ·
Pinsp:
5-65 cmH2O ·
Frequency:
1-100 bpm ·
I:E
Ration: 4:1-1:9 ·
Trends/
Logs: 72 hrs/ 1000 Events ·
Driviing
Gas: Oxygen (Standard) / Air (Optional) ·
Supply
Pressure: 45-100 PSI (310-700 kPa) ·
Minute
Volume: 0-40 lpm ·
inspiratory
pause: 0-50% of Ti ·
Adjustable
pressure relief: 0-70cm H2O ·
Supply
Gas Low Alarm: 250kpa ·
Respiratory
Manometer Pressure Gauge: (-)20 - (+) 100 cmH2O ·
Internal
Battery Backup: 120 mins. ·
It has survived not only five centuries, but also the leap into electronic typesetting, remaining essentially unchanged. Regarding any queries. |