A4 SIZE Printout ,INTERPRETIVE 12 CHANNEL ELECTROCARDIOGRAM ECG/EKG MACHINE. The CardioCare 2000 is an economically priced interpretive 12 channel electrocardiogram (ECG/EKG) machine that does not compromise on performance. Suitable for use in private practice, the ER, or hospitals. The CardioCare 2000 is designed for maximum ease of use and convenience.
|
ECG leads |
12 lead, simultaneous ECG and acquisition |
|
Dimension |
296 (W) x 305.5 (H) x 92.5 (D)mm, Approx.2.98 kg |
|
Recording channel |
3, 6, 12 channel and 1 channel (60 sec) |
|
Sensitivity |
5, 10, 20, auto (1-aVF: 10, V1-V6: 5) mm/mV, 12.5, 25, 50 mm/S |
|
Sampling rate |
500 samples/sec |
|
Filters |
AC (50/60Hz, -20dB or better) Muscle (25 - 35Hz, -3dB or better) Base line drift (0.1 Hz, -3dB or better) Low pass filter (off, 40Hz, 100Hz, 150Hz) |
|
Display |
2 x 16 character backlit LCD Display |
|
LCD display |
Sensitivity, speed, filter status, HR, printing form, rhythm lead |
|
LED indicator |
Signal quality, power source, battery |
|
Keyboard |
Membrane keyboard, Alphanumeric and symbol available |
|
Patient data |
ID, name, age, sex, height, weight |
|
Basic measurement |
Heart rate, PR int, QRS dur, QT/QTc, P-R-T axis |
|
Recorder |
Thermal print head, Thermal roll paper Report papers : width : A4 : 210mm or 8.5" , length : A4 : 300mm or 11" Effective writing width: 204mm Resolution : Vertical : 8 dots/mm, Horizontal : 16 dots/mm |
|
Electrical |
Internal noise : 20 V(p-p)max Internal circuit: Floating input Isolated and defibrillation protected Input impedance : > 10MW Input voltage range : > + 5 mV Common Mode Rejection : > + 100 dB DC offset voltage range : > + 300 mV Time constant : 3.2sec Patient leakage current : < 10 mA Frequency response 0.05-150Hz |
|
Signal quality control |
Disconnected lead detection |
|
Power |
Power supply : AC or built-in Battery (option) Power requirement : 100 - 240 Vac, 50/60Hz, 1.0 - 0.5 A Power consumption : 60W max |
|
Battery |
1 hour of normal use (approximately 100 automatic ECG printouts) |
|
Communication |
PC connection with RS-232 interface and LAN |
|
Safety |
Class I, Type BF |
|
Conformity |
CE, CSA, FDA, KFDA, SFDA, CCC |
|
Environment |
Operating humidity : 30 - 85 % Operating Temperature : 10 - 40 C Atmospheric pressure : 70 - 106 KPa |
|
Standard accessory |
Power cord 1 EA, Patient cable 1 EA, Limb 1 set (4 EA), Chest ball 1 set (6EA), Chart paper 1 EA, Operation manual 1 EA |
|
Options |
Rechargeable battery, Cart, Hanger, Bag, PC S/W |
* Specifications can be changed without prior notification