Multipara Patient Monitor, Model: YK-8000B

Multipara Patient Monitor, Model: YK-8000B
Spares & Service by Xavier Med Pvt. Ltd.

Availability: In stock
SKU: YK-8000B

Technical Specifications

Quality Standards and Classification

·        Anti-electroshock degree: Class-Ⅰ equipment (internal power supply)

·        TEMP/SpO 2 /NIBP: BF

·        ECG/Resp: CF

 

Application Range

·        Adult/ Pediatric/ Neonatal/ Medicine/ Surgery/ Operating Room/ ICU/ CCU

 

Display

·        12.1” real color TFT screen

 

Environment

working environment conditions

·        Temperature: Working temperature 0 40 ℃

·        Humidity: Working humidity ≤ 85 %

 

Shipping and storage conditions

·        Temperature: Transportation and storage temperature -20 60 ℃

·        Humidity: Transportation and storage humidity ≤ 93 %

 

Electrical Specifications

·        Power supply voltage: AC 100~240V

·        AC, power frequency: 50/60Hz, maximum input power 70VA Fuse is F2AL 250V

·        Working method: continuous work

·        Built-in lithium battery: d.c11.1V not less than 2000mA, working time not less than 2 hours.

 

Dimension and Weight

·        Product Size 262*336*84mm

·        product weight 2.72kg

 

ECG

·        Gain: X0.25, X0.5, X1, X2, Auto

·        Waveform speed: 12.5mm/s, 25mm/s, 50mm/s,

·        Sensitivity200uV (peak-to-peak)

Bandwidth:

·        Diagnostic mode: 0.05~130Hz

·        Monitoring mode: 0.5~40Hz

·        Operation mode: 1~20Hz

·        Common Mode Rejection Ratio:

·        Diagnostic mode: >90dB

·        Monitoring mode: >100dB

·        Operation mode: >100dB

·        Electrode polarization voltage: ±300mV

·        Input impedance≥5M

·        DC bias voltage: ±300mV

·        Calibration signal: 1mV (peak-to-peak), accuracy ±5%

ST segment detection measurement:

·        Measurement range: -2.0mV~+2.0mV

·        Measurement accuracy: within the range of -0.8mV~+0.8mV, the measurement error is ±0.02mV or ±10%, whichever is greater, other ranges are undefined

 

Trend data length

·        School limit list400 groups

·        Waveform playback6000 seconds

·        Trend table7 days

·        Trend graphup to 7 days

·        Alarm review60 groups

 

ST Segment

·        Maximum upper limit 2.0mv

·        Minimum lower limit -2.0mv

·        Single adjustment amount 0.1mv

 

NIBP

·        Measuring Range and Precision Range

·        Adult Systolic blood pressure 40270mmHg

·        Diastolic blood pressure 10215mmHg

·        Mean blood pressure 20235mmHg

·        Static pressure range 0300mmHg

·        Static pressure precision ±3mmHg

Pressure precision:

·        Max. average error: ±5mmHg

·        Max. standard deviation: 8mmHg

 

 

SpO2

·        Measuring range 0100%

·        Resolution 1%

·        The accuracy is within the range of 70% to 100%, and the measurement error should be ±2%; In the range of 0% to 69%, the measurement error is Undefined

 

Pulse Rate

·        Measuring range 30300bpm

·        Resolution 1bpm

·        Accuracy ±3bpm

·