Working Hours: 10AM - 6 PM (or)
Fill Service Request Form
with remote sensing Tab for charting the real time drug delivery of patient, so anaesthetist can monitor the workstation from any where within the Hospital.
FEATURES:
· Larger, Clearer user Interface
· 10.1 Inch high resolution display for excellent visibility across the OT
· Clear presentation of parameters, waveforms, and trends.
· Reduces eye strain during long procedures.
· Quick Release CO2 Canister System
· Heater integrated Circle Absorber
· Built-in flow sensor with no external tubing
· Reduced clutter and fewer connection points.
· Enhanced durability and long-term performance
TECHNICAL SPECIFICATIONS:
· Storage Space: Two spacious drawers for keeping essential anesthesia kit / accessories
· Castors & Foot Rest: Large roller bearing and Castors with front brakes & foot rest
· Writing Surface: Wide table top for writing
· Monitor shelf: Wide monitor shelf at eye level.
· Cylinder Yokes: Color coded gas specific (pin indexed) yokes with sliding stainless steel clamping bars for easy handling. Holding One O2 and One N2O 5 Ltrs. water capacity cylinders.
· Non-return/ Pressure Relief Valve: Minimizes risk of back flow of gases, blows off when pressure exceeds 125 Cm H2O
· Regulators: Designed for higher efficiency, long service life and reliability for O2 and N2O
· O2 Flush: Emergency oxygen flush switch at table level to give 25-75 Ltrs/min for emergencies
· O2 Failure Warning Alarm: Self activated electro-pneumatic audio visual warning device to indicate drop in O2 pressure below 2.5 Bar
· Nitro Lock: It enables N2O to cut off if Oxygen fails
· Hypoxic Guard: Mixing device to proportion the N2O in such a way that minimum of 25% O2 is always present in the breathing gas mixture
· Common Gas Outlet (CGO): Conveniently located CGO with ISO tapers for 22 & 15mm connections
· Pipeline Gas Inlets: Non-interchangeable screw threaded (NIST) pipeline inlets. In case of drop in piped gas pressure the pin index cylinders take over automatically
· Pressure Gauges: Larges diameter, color coded gauges fitted at convenient angle for better visibility and clarity. One for each of the pin indexed yokes and one each corresponding to piped gas inlet
· Selectatec Brackets: Twin Selectatec Block
· Breathing Circuits: Bains and Closed circuit provided as standard
CASCADE FLOW METER:
· Oxygen Low Flow: 0.05 - 1.0 lpm
· Oxygen High Flow: 1-10 lpm
· N2O Low Flow: 0.05-1.0 lpm
· N2O High Flow: 1-12 lpm
· Air: 0.2 - 15 lpm
PHYSICAL SPECIFICATION:
· Dimensions (mm): 1370 (H) x 960 (W) x 860 (D)
· Work Surface(mm): 842 (H) x 480 (W) x 220 (D)
· Drawer (mm) 104 (H) x 335 (W) x 306 (D)
· Weight: 100 Kg.
VENTILATOR TECHNICAL SPECIFICATIONS:
· Modes: VCV, PCV, V-SIMV+PSV, P-SIMV+PSV, PSV (Optional), AC-V, AC-P and Manual
· Electronic PEEP: Settable, 3-30 cmH2O
· Waveforms: Pressure, Flow and Volume
· Loops: Pressure vs Volume, Flow vs Volume
· Compensation: Fresh Gas and Compliance
· Tidal Volume: 20ml - 1500ml
· Pinsp: 5-65 cmH2O
· Frequency: 1-100 bpm
· I:E Ration: 4:1-1:9
· Trends/ Logs: 72 hrs/ 1000 Events
· Driviing Gas: Oxygen (Standard) / Air (Optional)
· Supply Pressure: 45-100 PSI (310-700 kPa)
· Minute Volume: 0-40 lpm
· inspiratory pause: 0-50% of Ti
· Adjustable pressure relief: 0-70cm H2O
· Supply Gas Low Alarm: 250kpa
· Respiratory Manometer Pressure Gauge: (-)20 - (+) 100 cmH2O
· Internal Battery Backup: 120 mins.
·
It has survived not only five centuries, but also the leap into electronic typesetting, remaining essentially unchanged.
Regarding any queries.