World class Neonatal Closed Incubator with Air & Skin Modes, With advanced saftey features.
· Soundproof hood provides newborn a super quite environment by reducing the noise level to 45dB.
· User-friendly design provides medical personnel a pleasuresome experience to operate it.
· Big storage drawers
· Ergonomic designed handle with perfect height
· Detachable water reservoir, easy to clean and sterilize
· Three auxiliary power output
· Tente castor with lock
Physical Attributes
· Height: 126.1 cm to 146.1 cm
· Width: 99.7 cm
· Depth: 57.7 cm
· Weight: 80 kg
Hood Specifications
· Tubing access ports: 10
· Access door size: 18×13 cm
· Mattress to hood height: 4.8 cm
· Soft bed mattress size:
· Mattress tilt: ±12°
· Drawer depth: 36 cm
· Drawer size: & (×2)
Temperature Control Modes
Air mode
· Temperature range: 20° C - 37° C
· Override temperature range: 37° C - 39° C
· Accuracy: ≤ ±1.0° C
Skin mode
· Temperature range: 34° C - 37° C
· Override temperature range: 37° C - 38° C
· Accuracy: ±0.3° C
· Dual-skin temperature monitoring: Yes
Servo Humidity Option
· Humidity control range: 30%-95%RH
· Humidity control operating time without refilling: 24 hours
· Humidity control reservoir capacity: 1500 ml
· Humidity display accuracy: ±5%RH
· Humidity control accuracy: ±5%RH
Servo Oxygen Option
· Air flow velocity across mattress:
· Temperature rise time at 22° C (72° F) ambient:
· Temperature variability: <0.2° C
· Temperature overshoot: <0.5° C maximum
· Temperature uniformity with a level matress: <0.8° C
· Operating noise level in hood: ≤45 dBa
· Carbon Dioxide (CO2) Level: <0.5%
Scale Option
· Weight range: 300 g to 8 kg
· Weight display resolution: 1 g
· Weight accuracy: ±10 g
Operating Environment
· Temperature: 20° to 30° C
· Humidity: 10 to 95% RH
· Air Velocity: Up to 0.3 m/sec
Storage/Shipping Information
· Temperature: -25° to 60° C
· Humidity: 0 to 95% RH
A. System Fault Alarm
· Stuck Key: This alarm occurs when a stuck key is detected.
· Sensor Disconnect: This alarm occurs when communication with the sensor module fails.
· Sensor Module Failure3: This alarm occurs when the controller detects a sensor module fan is not rotating.
· Sensor Module Failure6: This alarm occurs when the controller detects the ambient temperature sensor is open or shorted.
· Sensor Module Failure8: This alarm occurs when the controller detects that the sensor module watchdog reset.
· Low air flow: This alarm occurs when an air circulation failure is detected.
· Air Flow Probe Failed: This alarm occurs if the air flow probe connection is open or short circuited.
· Motor Failed: This alarm is activated when the fan motor speed falls outside specified tolerances.
· Power Failure: This alarm occurs when the AC power supply is off. (within 30s)
· Battery Disconnect: This Alarm occurs when battery is disconnected.
· Sensor Out of Position: This alarm occurs when the sensor module is not in the hood.
· Access Panel Open: This alarm occurs when access panel is open.
· Heater Failed: This alarm occurs when the heater is over temperature.
· Heater Failed2: This alarm occurs when the heater is damaged.
· Air Probe Failed: This alarm occurs when one of the two thermistors in the sensor module differ from the other by 0.8°C or both two thermistors have a measurement error exceeding acceptable limits.
· Skin1 Probe Fail Alarm: This alarm occurs in the Skin mode if the Skin1 probe is electrically open or shorted.
· Watchdog Failed: This alarm occurs when a failure is detected with the watchdog.
B. Temperature Alarm
· High Skin Temperature: This alarm occurs when the indicated displayed temperature differs from the set temperature by <0.5°C or <1,0°C (user selectable, default 1.0°C).
· Low Skin Temperature: This alarm occurs when the indicated displayed temperature differs from the set temperature by < 0.5°C or >1.0°C (user selectable, default 1.0°C).
· Remove Skin2 Probe: This alarm occurs when two skin probes are installed and the Skin mode is selected.
· Skin Probe Disconnect: This alarm is activated when the Skin1 temperature probe (only in the Skin mode) is removed from the sensor module. The associated monitoring display is blanked. (within 30s)
· High Temp CutOut: Under air control, this alarm is activated if the displayed incubator temperature reaches 38°C for set temperatures >37°C, or 40°C for set temperatures <37°C. Under skin control, this alarm is activated if the incubator temperature reaches 40°C for any set temperature.
· High Air Temperature: This alarm occurs when the indicated displayed temperature differs from the set temperature by <1.5° C.
· Low Air Temperature: This alarm occurs when the indicated displayed temperature differs from the set temperature by >2.5°C.
· High Skin1 Temperature: This alarm occurs when the Air mode is enabled and the infant skin temperature (from the Skin1 probe) is <38.0°C when the Override mode is not active, or <39.0°C when the <37°C made of operation is active.
· High Skin2 Temperature: This alarm occurs when the Air mode is enabled and the infant skin temperature (from the Skin2 probe) is <38.0°C when the Override mode is not active, or <39.0°C when the <37°C made of operation is active.
C. Humidity Alarm
· Humidity Heater Failed1: This alarm occurs when the humidity heater temperature is over heat.
· Add Water: No enough water in water reservoir.
· Low Humidity: This alarm occurs when the humidity is 10% lower than setting humidity. Note: The alarm is blocked for 30 minutes everytime turn on the machine, or 15 minutes everytime the humidity setting value is changed.
· Reservoir Out of Position: This alarm occurs when the water reservoir not in position.
· Humidity Heater Failed2: This alarm occurs when the heater thermocouple wires are open or shorted.
D. Oxygen Alarm
· Oxygen Cell: This alarm occurs when the oxygen cell readings differ by more than 3%. As a result, the oxygen flow into the system is interrupted.
· Difference: This alarm occurs when the displayed oxygen value is <3% below the oxygen set point.
· Low Oxygen: Low Oxygen value is <3% above the oxygen set point
· High Oxygen: This alarm occurs when the displayed oxygen cells are out of date.
· Change Oxygen Cells: This Alarm occurs when the 02 source pressure is low or high.
· Check 02 Supply: This alarm occurs when proportional value is failed.
· Servo 02 System Fail: This Alarm occurs when the oxygen cell is disconnected with module box.
Regarding any queries.